Maryland Bids > Bid Detail

Install Copper and Fiber Optic cable at the ARMAG Building at Cheltenham, MD

Agency: HOMELAND SECURITY, DEPARTMENT OF
Level of Government: Federal
Category:
  • N - Installation of Equipment
Opps ID: NBD00159406576794721
Posted Date: Jul 15, 2023
Due Date: Aug 15, 2023
Solicitation No: 70LGLY23QSSB00067
Source: https://sam.gov/opp/9f0744dfe5...
Follow
Install Copper and Fiber Optic cable at the ARMAG Building at Cheltenham, MD
Active
Contract Opportunity
Notice ID
70LGLY23QSSB00067
Related Notice
Department/Ind. Agency
HOMELAND SECURITY, DEPARTMENT OF
Sub-tier
FEDERAL LAW ENFORCEMENT TRAINING CENTER
Office
FLETC GLYNCO OPERATIONS
Looking for contract opportunity help?

Procurement Technical Assistance Centers (PTACs) are an official government contracting resource for small businesses. Find your local PTAC (opens in new window) for free government expertise related to contract opportunities.

General Information
  • Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
  • All Dates/Times are: (UTC-04:00) EASTERN STANDARD TIME, NEW YORK, USA
  • Original Published Date: Jul 15, 2023 11:53 am EDT
  • Original Date Offers Due: Aug 15, 2023 04:30 pm EDT
  • Inactive Policy: 15 days after date offers due
  • Original Inactive Date: Aug 30, 2023
  • Initiative:
    • None
Classification
  • Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
  • Product Service Code: N059 - INSTALLATION OF EQUIPMENT- ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS
  • NAICS Code:
    • 238210 - Electrical Contractors and Other Wiring Installation Contractors
  • Place of Performance:
    Cheltenham , MD 20588
    USA
Description

  1. Background



This Statement of Work (SOW) establishes and defines the requirements for the engineering, furnishing, installation, testing and documentation of inside and outside plant fiber optic and copper cabling at Cheltenham, MD.




  1. Scope of Work



The contractor shall provide all personnel, equipment, tools, materials, supervision, and all other components necessary to install, test and document inside and outside plant fiber optic and copper cabling at Cheltenham, MD. All work performed in the design and installation shall conform to BICSI (Building Industry Consulting Services International) specifications to ensure consistency with current codes, standards, and regulations. The following BICSI publications apply. Outside Plant Design Reference Manual, 4th Edition and Telecommunications Distribution Methods Manual, 12th edition.




  1. General.


    1. Cable Testing. All copper cables will be tested in accordance with BICSI specifications to ensure no damage has occurred to the cable during installation. All copper cables shall be tested for cable faults prior to and after installation has been completed. If the cable is damaged during installation, the contractor shall replace the cable with one that is undamaged. All cable terminals and information boxes interface units shall be labeled with machine-generated labels. All cables shall be labeled at all termination points, building entrance terminals, patch panels, manholes, hand holes, and at all splice entrance/exit points.

    2. Site Restoration. All non-paved surfaces (grass, sod, gravel, etc.) must be restored within 7 days. Trenches and splice pits must be mechanically compacted to compensate for future earth settlement. All roads, streets, sidewalks of concrete or asphalt construction must be restored or repaved within 3 days from the time of backfilling and compaction.

    3. Grounding. Contractor shall ensure all equipment are secured and grounded to industry standards.



  2. Description of Task

    1. Task 1: Material to Install Copper and Fiber Optic cable at the ARMAG Building at Cheltenham, MD.

      1. List of materials to be provided by the contractor.

      2. Approximately 650’ Shielded Twisted Pair Copper Cable (STP)

      3. Approximately 350’ 6 Strand Single Mode Fiber Optic Cable

      4. Two (2) Wal Mount 12 Port Fiber Optic Patch Panel

      5. Twelve (12) SC Type Fiber Connectors

      6. Four (4) Lightning Arresters

      7. One 17”x30”x18” Communications Handhole

      8. Approximately 300 Ft of 2” schedule 40 PVC conduit



    2. Task 2: Install Copper and Fiber Optic cable at the ARMAG Building at Cheltenham, MD.

      1. Contractor shall provide and install a 17”x30”x18” handhole 2” schedule 40 PVC conduit from the existing handhole near bldg. 53 into the new hand hole installed behind the ARMAG bldg. (See Aerial Photo in Attachment 1 below)

      2. Contractor shall provide and install a 2” schedule 40 PVC conduit from the existing handhole near bldg. 53 into the new hand hole installed behind the ARMAG bldg.

      3. Contractor shall provide and install two (2) outside plant grade CAT 6 cable through the newly installed handhole and conduit into the ARMAG building.

      4. Contractor shall terminate both ends of the STP cable onto a lightning arrester terminal.

      5. Contractor shall provide and install a twelve (12) strand single mode fiber optic cable from bldg. 53 IT closet through the conduits and manholes into the ARMAG bldg.

      6. Contractor shall terminate both ends of the 12-strand fiber cable onto fiber optic patch panel using SC fiber optic connectors.

      7. Contractor shall tag and label the cable and terminal.

      8. Contractor shall test label and tag the terminal, cables, and patch panels.






Attachments/Links
Contact Information
Contracting Office Address
  • 1131 CHAPEL CROSSING ROAD, BLDG 94
  • Brunswick , GA 31524
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Jul 15, 2023 11:53 am EDTCombined Synopsis/Solicitation (Original)

TRY FOR FREE

Not a USAOPPS Member Yet?

Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.