Maryland Bids > Bid Detail

6145--Electrical cabling/components for air curtain Loch Raven VAMC Bldg. One Main Entrance

Agency: VETERANS AFFAIRS, DEPARTMENT OF
Level of Government: Federal
Category:
  • 61 - Electric Wire, and Power and Distribution Equipment
Opps ID: NBD00159881548312546
Posted Date: Jun 7, 2023
Due Date: Jun 21, 2023
Solicitation No: 36C24523Q0715
Source: https://sam.gov/opp/a45e8fa622...
Follow
6145--Electrical cabling/components for air curtain Loch Raven VAMC Bldg. One Main Entrance
Active
Contract Opportunity
Notice ID
36C24523Q0715
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
245-NETWORK CONTRACT OFFICE 5 (36C245)
Looking for contract opportunity help?

Procurement Technical Assistance Centers (PTACs) are an official government contracting resource for small businesses. Find your local PTAC (opens in new window) for free government expertise related to contract opportunities.

General Information
  • Contract Opportunity Type: Sources Sought (Original)
  • All Dates/Times are: (UTC-04:00) EASTERN STANDARD TIME, NEW YORK, USA
  • Original Published Date: Jun 07, 2023 10:01 am EDT
  • Original Response Date: Jun 21, 2023 10:00 am EDT
  • Inactive Policy: Manual
  • Original Inactive Date: Jul 21, 2023
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: 6145 - WIRE AND CABLE, ELECTRICAL
  • NAICS Code:
    • 238210 - Electrical Contractors and Other Wiring Installation Contractors
  • Place of Performance:
    Department of Veterans Affairs Loch Raven VAMC Baltimore , MD 21218
    USA
Description
Scope of Work:
Building #1 Air Curtain Electrical Connection
512-23-2-849-0114

General:
The Loch Raven VA Medical Center requests installation of electrical lines and components for heated air curtain located in building #1 located at 3900 Loch Raven Blvd. Baltimore, Md.

About the site:
TheƂ Loch Raven VA Community Living & Rehabilitation Center specializes in providing rehabilitation and recreation therapy for our recovering veterans. The main building also provides hospice, nursing home care and care for patients with Alzheimer s.

Period of Performance: TBD

Scope of Work:
Contractor to supply all labor, supervision, equipment, tools, and materials necessary to perform installation of electrical wires and components for heated air curtain located at building #1 main entrance. Existing air curtain was found in a state of disrepair and heated air curtain is required to prevent temperatures from dropping when entering the building.

Contractor shall remove and replace any defective electrical components currently in place with existing air curtain. Contractor to relocate x4 120 volt circuit breakers in breaker panel located in room 2A-09. These circuits are essential by code to be moved do to the size breaker required for existing job.
Contractor to furnish and install x1 24- circuit, 3-phase main lug panel with feed from NQOD panel.
Contractor to furnish and install 60 amp breaker for existing air curtain and label.
Safety Precautions: The Contractor shall comply with all applicable Federal, State and local legal requirements regarding workers health and safety. The requirements include but are not limited to, those found in Federal and State Occupational Safety and Health Act (OSHA) statutes and regulations, such as applicable provisions of Title 29, Code of Federal Regulations (CFR) Parts 1910 and 1926. Contractor is solely responsible for determining the legal requirements that apply to activities and shall ensure safe and healthful working conditions for its employees.
Contractor shall assume the responsibility to guard against causing of fires and/or explosions and to protect Government Property.
The Contractor shall perform the work in a manner consistent with the area security and fire safety regulations especially about exits and exit way access. Utility shutdowns shall not compromise security, communication or fire safety for occupants.
No flammable liquids shall be stored or used in the medical center.
The necessary number and appropriate types of portable fire extinguishers are required per National Fire Protection Agency (NFPA) 10 and NFPA 241.
The Contractor shall receive from the COR a permit for all cutting, welding, and soldering. All permits shall be prominently displayed during all activities.
All necessary precautions shall be taken by the contractor to prevent accidental operation of any existing smoke detectors or sprinkler heads.

HAZARDOUS MATERIAL REPORTING:
A. The Contractor shall maintain hazardous material inventories and material safety data sheets (MSDS) for all hazardous materials (as defined in CFR 1910.120, 40 CFR s 355, 370, & 372) to be stored and used on this Medical Center. Hazardous materials must be inventoried when received and at the project s completion. The amounts used shall be maintained for the project duration.

B. Hazardous Materials Inventories, Material Safety Data Sheets and material quantities used shall be submitted to the Contracting Officer for approval and copies furnished to the Contracting Officers Technical Representative.

C. In the event of a spill, Contractor shall immediately notify the Contracting Officer s Technical Representative as well as the Contracting Officer. The Contractor shall be solely responsible for the expense of any cleanup and / or damage resulting of such spill, and the cleanup shall be in accordance with the applicable provisions of 40 CFR Part 761.

Attachments/Links
Contact Information
Contracting Office Address
  • 8849 International Drive Suite 215
  • LINTHICUM , MD 21090
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Jun 07, 2023 10:01 am EDTSources Sought (Original)

TRY FOR FREE

Not a USAOPPS Member Yet?

Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.